Description
LPG Manometer is used in LPG dispenser.
1.Technical Specification:
Accuracy: |
2.5% |
Pressure: |
0-4MPa |
2.Details of Operation:
1) It is generally apply to 3/4 of the limitation when measure the pressure and 2/3 for the pressure fluctuations.
2)Working temperature: -40 ~ 70 °C, relative humidity≤80%.
3)The common type manometer should be avoid to severe vibration or pressure fluctuations mutations and should be used shock-proof type manometer for severe vibration or pressure fluctuations.
4)Meter shall be installed vertically and avoid to moving dial shell in the installation.
5)In use of the meter, must be calibration one every 3 months.